Many soils swell to some degree as their water content and degree of saturation increase. Wetting reduces effective stress, which can cause the soil to expand. Free swelling strain is the ratio of heave to the original sample height and is typically around 1% for this mechanism.
In certain fine-grained soils known as expansive soils, free swelling strain can exceed 10%. Excessive total and differential movements can result, together with high contact pressures against foundations, retaining structures or tunnel linings. Possible responses include adapting the foundations, stabilising the soil or combining the two approaches.
The HBC® system is a ground treatment technique developed by Hydro Buildings Consolidation S.r.l. It controls soil saturation by maintaining a stable water content. A purpose-built system supplies water through perforated pipes installed beneath the foundations. Trenchless installation minimises disturbance when treating existing buildings.

WeSI Geotecnica was commissioned to study how saturation changes over time and how the system could be optimised. The study modelled the treatment beneath an existing building on strip foundations. The finite element analyses used Bishop’s effective stress formulation for partially saturated soil and tracked changes in suction and the resulting building heave as the clay swelled. The initial degree of saturation determined the initial suction distribution.

The soil water characteristic curve relates suction to the degree of saturation. WeSI Geotecnica developed a procedure to limit the cost of hydraulic characterisation. The design study evaluated how different numbers of water distribution lines affected the time-dependent heave of the structure.

Where ground movement has already damaged a building, the analyses help assess the effects of changing saturation and calibrate the treatment to improve its effectiveness relative to cost.
Three-dimensional finite element modelling can assess geometries that cannot be represented by a plane-strain model. It can estimate disturbance during wetting and evaluate treatment effectiveness over the short and long term, taking into account primary consolidation, creep and interaction with adjacent structures.
For enquiries: Hydro Buildings Consolidation S.r.l. Via A.Tiarini 27/a - 40129 Bologna - info@hbc-consolidamenti.it